What's Wrong Here? Hint: An Alarming Identification Method

March 15, 2024
Can you spot the Code violation in this photo?

How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Here's your chance to moonlight as an electrical inspector and second-guess someone else's work from the safety of your living room or office. Can you identify the specific Code violation(s) in this photo? Note: Submitted comments must include specific references from the 2023 NEC. 

Hint: An alarming identification method

Tell Them What They've Won…

Using the 2023 NEC, correctly identify the Code violation(s) in this month's photo — in 200 words or less — and you could win an Arlington Industries 18-in. Slider Bar and plastic box for mounting between studs with non-standard spacing. E-mail your response, including your name and mailing address, to [email protected], and Russ will select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Note that submissions without an address will not be eligible to win.

January Winners

Our winners this month were Mark De Angelis, an EC&M reader from Pembroke, N.H.; Ronnie Morales, a fire systems inspector for the City of Temecula, Calif.; and Cassandra Knapp, a participant from Corinth, Miss. They were able to correctly cite some of the Code violations in this photo.

Section 408.7 requires unused circuit breaker openings to be closed with closures identified for that purpose or some other approved means that could provide protection equivalent to the enclosure walls. Section 110.12(A) also requires unused openings to be closed up. Installing circuit breakers from several different manufacturers may be a violation of Sec. 110.3(B) if the breakers are not listed for use with this particular panelboard.

The lack of descriptors for many of the circuits is a violation of Sec. 408.4(A). Each circuit must be clearly marked to indicate its specific purpose. Even the spare positions containing an overcurrent device are required to be marked to indicate they are spares, per Sec. 408.4(A)(3). Lastly, Sec. 110.27(A) requires live parts to be guarded against accidental contact by approved enclosures.

About the Author

Russ LeBlanc | Owner

Russ started in the electrical trade as an apprentice in 1985. He worked his way up to become a Journeyman Electrician and then eventually became a Master Electrician and Licensed Construction Supervisor. In 1999 Russ become an Electrical Instructor for The Peterson School of Engineering in Massachusetts where he developed his passion for teaching, and quickly became Department Head of Electrical Instruction. Russ has taught thousands of apprentices, electricians, engineers, inspectors, and other electrical professionals during his career as an instructor. He continues to provide electrical professionals with Electrical Code seminars, Arc-Flash Awareness training seminars and educational material through his LeBlanc Consulting Services in North Reading, MA whose specialty is educating electricians. He has been an active member of the NFPA Electrical Section and has authored hundreds of National Electrical Code proposals and comments which have become Code rules to improve the safety for the electrical industry. Russ is also an IAEI certified Electrical Inspector.

Please visit www.russleblanc.net for more information.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Strut Comparison Chart

Conduit support systems are an integral part of construction infrastructure. Compare steel, aluminum and fiberglass strut support systems.

Electrical Conduit for Bridges Guide

Learn about electrical conduit for bridge projects.

Don't Let Corrosion Disrupt Your Next Project

The Complete Corrosion eGuide for Industrial Electrical Systems will help you avoid corrosion and its effects so you can spec for success for successful project outcomes.

Strut Corrosion Guide

Learn how Champion Strut™ benefits projects with corrosion resistance.